1,788 research outputs found

    Sound-Induced Flash Illusion is Resistant to Feedback Training

    Get PDF
    A single flash accompanied by two auditory beeps tends to be perceived as two flashes (Shams et al. Nature 408:788, 2000, Cogn Brain Res 14:147–152, 2002). This phenomenon is known as ‘sound-induced flash illusion.’ Previous neuroimaging studies have shown that this illusion is correlated with modulation of activity in early visual cortical areas (Arden et al. Vision Res 43(23):2469–2478, 2003; Bhattacharya et al. NeuroReport 13:1727–1730, 2002; Shams et al. NeuroReport 12(17):3849–3852, 2001, Neurosci Lett 378(2):76–81, 2005; Watkins et al. Neuroimage 31:1247–1256, 2006, Neuroimage 37:572–578, 2007; Mishra et al. J Neurosci 27(15):4120–4131, 2007). We examined how robust the illusion is by testing whether the frequency of the illusion can be reduced by providing feedback. We found that the sound-induced flash illusion was resistant to feedback training, except when the amount of monetary reward was made dependent on accuracy in performance. However, even in the latter case the participants reported that they still perceived illusory two flashes even though they correctly reported single flash. Moreover, the feedback training effect seemed to disappear once the participants were no longer provided with feedback suggesting a short-lived refinement of discrimination between illusory and physical double flashes rather than vanishing of the illusory percept. These findings indicate that the effect of sound on the perceptual representation of visual stimuli is strong and robust to feedback training, and provide further evidence against decision factors accounting for the sound-induced flash illusion

    Vascular Remodeling in Hypertension

    Get PDF
    Cerebral arterioles in stroke-prone spontaneously hypertensive rats (SHRSP) paradoxically become more distensible, despite hypertrophy of the vessel wall. Cerebral arterioles in SHRSP also undergo remodeling with a reduction in external diameter. Based on these findings, we have proposed the concept that remodeling of cerebral arterioles may be an important mechanism, in addition to hypertrophy, for encroachment on the vascular lumen in SHRSP. The purpose of this review is threefold. First, consequences of vascular hypertrophy that have been proposed previously are reviewed with an emphasis on the hypothesis that encroachment on the vascular lumen by hypertrophy is an important mechanism of altered vascular responses in chronic hypertension. Second, the concept of vascular remodeling is considered with an emphasis on the possibility that remodeling with a reduction in external diameter may contribute importantly to altered cerebral vascular responses in SHRSP. Finally, possible mechanisms of vascular remodeling are considered with an emphasis on the hypothesis that a reduction in external diameter may be related to a decrease in the length of individual smooth muscle cells without an increase in cell number, or an increase in the number of times each smooth muscle cell wraps around the arteriole

    Multisensory causal inference in the brain

    Get PDF
    At any given moment, our brain processes multiple inputs from its different sensory modalities (vision, hearing, touch, etc.). In deciphering this array of sensory information, the brain has to solve two problems: (1) which of the inputs originate from the same object and should be integrated and (2) for the sensations originating from the same object, how best to integrate them. Recent behavioural studies suggest that the human brain solves these problems using optimal probabilistic inference, known as Bayesian causal inference. However, how and where the underlying computations are carried out in the brain have remained unknown. By combining neuroimaging-based decoding techniques and computational modelling of behavioural data, a new study now sheds light on how multisensory causal inference maps onto specific brain areas. The results suggest that the complexity of neural computations increases along the visual hierarchy and link specific components of the causal inference process with specific visual and parietal regions

    Theory and Practice of Shear/Stress Strain Gage Hygrometry

    Get PDF
    Mechanical hygrometry has progressed during the last several decades from crude hygroscopes to state-of-the art strain-gage sensors. The strain-gage devices vary from different metallic beams to strain-gage sensors using cellulose crystallite elements, held in full shear restraint. This old technique is still in use but several companies are now actively pursuing development of MEMS miniaturized humidity sensors. These new sensors use polyimide thin film for water vapor adsorption and desorption. This paper will provide overview about modern humidity sensors

    Extra- and intra-cellular accumulation of platinum group elements by the marine microalga, Chlorella stigmatophora.

    Get PDF
    To better understand the marine biogeochemistry of the platinum group elements (PGE), Rh(III), Pd(II) and Pt(IV) were added in combination and at ppb concentrations to cultures of the marine microalga, Chlorella stigmatophora, maintained in sea water at 15 °C and under 60 μmol m(-2) s(-1) PAR. The accumulation of PGE was established in short-term (24-h) exposures, and under varying conditions of algal biomass and PGE concentration, and in a longer-term exposure (156-h) by ICP-MS analysis of sea water and nitric acid digests and EDTA washes of the alga. In short-term exposures, and under all conditions, the extent of accumulation by C. stigmatophora was in the order: Rh > Pd >> Pt; and Pd was internalised (or resistant to EDTA extraction) to a considerably greater extent than Rh and Pt. Accumulation isotherms were quasi-linear up to added PGE concentrations of 30 μg L(-1) and all metals displayed a significant reduction in accumulation on a weight-normalised basis with increasing density (biomass) of C. stigmatophora, an effect attributed to the production of exudates able to stabilise metals in sea water through complexation. In the longer-term exposure, kinetic constraints on the reactivities of Rh and, in particular, Pt, resulted in final degrees of accumulation and internalisation by C. stigmatophora that were greatest for Rh and similar between Pd and Pt. Among the PGE, therefore, Rh is predicted to participate in biological removal and transport processes in the marine environment to the greatest extent while decoupling in the biogeochemistries of Pd and Pt is predicted in shorter-term or more transient processes

    Tunable Fiber Bragg Grating Ring Lasers using Macro Fiber Composite Actuators

    Get PDF
    The research reported herein includes the fabrication of a tunable optical fiber Bragg grating (FBG) fiber ring laser (FRL)1 from commercially available components as a high-speed alternative tunable laser source for NASA Langley s optical frequency domain reflectometer (OFDR) interrogator, which reads low reflectivity FBG sensors. A Macro-Fiber Composite (MFC) actuator invented at NASA Langley Research Center (LaRC) was selected to tune the laser. MFC actuators use a piezoelectric sheet cut into uniaxially aligned rectangular piezo-fibers surrounded by a polymer matrix and incorporate interdigitated electrodes to deliver electric fields along the length of the piezo-fibers. This configuration enables MFC actuators to produce displacements larger than the original uncut piezoelectric sheet. The FBG filter was sandwiched between two MFC actuators, and when strained, produced approximately 3.62 nm of wavelength shift in the FRL when biasing the MFC actuators from 500 V to 2000 V. This tunability range is comparable to that of other tunable lasers and is adequate for interrogating FBG sensors using OFDR technology. Three different FRL configurations were studied. Configuration A examined the importance of erbium-doped fiber length and output coupling. Configuration B demonstrated the importance of the FBG filter. Configuration C added an output coupler to increase the output power and to isolate the filter. Only configuration C was tuned because it offered the best optical power output of the three configurations. Use of Plastic Optical Fiber (POF) FBG s holds promise for enhanced tunability in future research

    Infrasonic Stethoscope for Monitoring Physiological Processes

    Get PDF
    An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece

    Tunable Optical Assembly with Vibration Dampening

    Get PDF
    Since their market introduction in 1995, fiber Bragg gratings (FBGs) have emerged as excellent means of measuring such parameters as strain and temperature. Distributed-grating sensing is particularly beneficial for such structural-health monitoring applications such as those of 'smart' structures or integrated vehicle health management in aerospace vehicles. Because of the variability of their output wavelengths, tunable lasers have become widely used as means of measuring FBGs. Several versions of a lightweight assembly for strain-tuning an FBG and dampening its vibrations have been constructed. The main components of such an assembly are one or more piezoelectric actuators, an optical fiber containing one or more Bragg grating(s), a Bragg-grating strain-measurement system, and a voltage source for actuation. The piezoelectric actuators are, more specifically, piezoceramic fiber composite actuators and, can be, still more specifically, of a type known in the art as macro-fiber composite (MFC) actuators. In fabrication of one version of the assembly, the optical fiber containing the Bragg grating(s) is sandwiched between the piezoelectric actuators along with an epoxy that is used to bond the optical fiber to both actuators, then the assembly is placed in a vacuum bag and kept there until the epoxy is cured. Bonding an FBG directly into an MFC actuator greatly reduces the complexity, relative to assemblies, that include piezoceramic fiber composite actuators, hinges, ferrules, and clamp blocks with setscrews. Unlike curved actuators, MFC actuators are used in a flat configuration and are less bulky. In addition, the MFC offers some vibration dampening and support for the optical fiber whereas, in a curved piezoelectric actuator assembly, the optical fiber is exposed, and there is nothing to keep the exposed portion from vibrating

    Curved Piezoelectric Actuators for Stretching Optical Fibers

    Get PDF
    Assemblies containing curved piezoceramic fiber composite actuators have been invented as means of stretching optical fibers by amounts that depend on applied drive voltages. Piezoceramic fiber composite actuators are conventionally manufactured as sheets or ribbons that are flat and flexible, but can be made curved to obtain load-carrying ability and displacement greater than those obtainable from the flat versions. In the primary embodiment of this invention, piezoceramic fibers are oriented parallel to the direction of longitudinal displacement of the actuators so that application of drive voltage causes the actuator to flatten, producing maximum motion. Actuator motion can be transmitted to the optical fiber by use of hinges and clamp blocks. In the original application of this invention, the optical fiber contains a Bragg grating and the purpose of the controlled stretching of the fiber is to tune the grating as part of a small, lightweight, mode-hop-free, rapidly tunable laser for demodulating strain in Bragg-grating strain-measurement optical fibers attached to structures. The invention could also be used to apply controllable tensile force or displacement to an object other than an optical fiber

    Infrasonic Stethoscope for Monitoring Physiological Processes

    Get PDF
    An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece
    • …
    corecore